Traductoare de cuplu

General Details

Gama NORBAR de traductoare de cuplu include: Traductorii montati pe flansa (FMT), Traductoarele statice, traductoare de cuplu dinamic (rotativ) si traductoare inelare pentru a fi utilizate cu multiplicatoarele de cuplu NORBAR.
Toate sunt „SMART” (inteligente), ceea ce înseamnă că au un circuit de memorie integrat care conține informații esențiale cu privire la traductor pe care instrumentele NORBAR o recunosc imediat.

Cod FMT (Flange Mounted Transducers)
50671.LOG* 0.04-2 N.m 1/4″ sq. dr. with Joint Simulator
50671.IND* 0.04-2 N.m 1/4″ sq. dr. with Joint Simulator
50672.LOG 0.5-10 N.m 1/4″ sq. dr. with Joint Simulator
50672.IND 0.5-10 N.m 1/4″ sq. dr. with Joint Simulator
50673.LOG 1.25-25 N.m 1/4″ + 3/8″ sq. dr. with Joint Simulator
50673.IND 1.25-25 N.m 1/4″ + 3/8″ sq. dr. with Joint Simulator
50677.LOG* 0.4-20 lbf.in 1/4″ sq. dr. with Joint Simulator
50677.IND* 0.4-20 lbf.in 1/4″ sq. dr. with Joint Simulator
50678.LOG 5-100 lbf.in 1/4″ sq. dr. with Joint Simulator
50678.IND 5-100 lbf.in 1/4″ sq. dr. with Joint Simulator
50679.LOG 12.5-250 lbf.in 1/4″ + 3/8″ sq. dr. with Joint Simulator
50679.IND 12.5-250 lbf.in 1/4″ + 3/8″ sq. dr. with Joint Simulator

* If using this transducer with a Series 1 TST or TTT (Part No. s 43198 – 43201)

Cod FMT (Flange Mounted Transducers)
50674.LOG 7.5-150 N.m 1/2″+ 3/8″sq. dr. with Joint Simulator
50674.IND 7.5-150 N.m 1/2″+ 3/8″sq. dr. with Joint Simulator
50680.LOG 5-100 lbf.ft 1/2″+ 3/8″sq. dr. with Joint Simulator
50680.IND 5-100 lbf.ft 1/2″+ 3/8″sq. dr. with Joint Simulator
50675.LOG 20-400 N.m 1/2″+ 3/4″ sq. dr.
50675.IND 20-400 N.m 1/2″+ 3/4″ sq. dr.
50681.LOG 12.5-250 lbf.ft 1/2″+ 3/4″ sq. dr.
50681.IND 12.5-250 lbf.ft 1/2″+ 3/4″ sq. dr.
Cod FMT (Flange Mounted Transducers)
50676.LOG 30-1500 N.m 1/2″, 3/4″ + 1″ sq. dr.
50676.IND 30-1500 N.m 1/2″, 3/4″ + 1″ sq. dr.
50682.LOG 20-1000 lbf.ft 1/2″, 3/4″ + 1″ sq. dr.
50682.IND 20-1000 lbf.ft 1/2″, 3/4″ + 1″ sq. dr.
TD1.CCW Counter clockwise calibration for FMT & STB when ordered with new unit

Includes integral transducer lead with connector to suit TST, TTT andT-Box XL™

Cod STATIC TRANSDUCERS
50587.xxx* 0.1-1 N.m 1/4″ M x 1/4″ F
50588.xxx 0.25-2.5 N.m 1/4″ M x 1/4″ F
50589.xxx 0.5-5 N.m 1/4″ M x 1/4″ F
50590.xxx 1-10 N.m 1/4″ M x 1/4″ F
50591.xxx 2.5-25 N.m 3/8″ M x 3/8″ F
50592.xxx 5-50 N.m 3/8″ M x 3/8″ F
50593.xxx 10-100 N.m 1/2″ M x 1/2″ F
50594.xxx 25-250 N.m 1/2″ M x 1/2″ F
50701.xxx 25-250 N.m 3/4″ M x 3/4″ F
50596.xxx 50-500 N.m 3/4″ M x 3/4″ F
50772.xxx 100-1000 N.m 1″ M x 1″ F
50766.xxx 150-1500 N.m 1″ M x 1″ F
50611.xxx 0.1-1 lbf.ft 1/4″ M x 1/4″ F
50615.xxx 0.5-5 lbf.ft 1/4″ M x 1/4″ F
50618.xxx 1-10 Ibf.ft 1/4″ M x 1/4″ F
50620.xxx 2.5-25 lbf.ft 3/8″ M x 3/8″ F
50622.xxx 5-50 lbf.ft 3/8″ M x 3/8″ F
50624.xxx 10-100 lbf.ft 1/2″ M x 1/2″ F
50625.xxx 25-250 lbf.ft 1/2″ M x 1/2″ F
50702.xxx 25-250 lbf.ft 3/4″ M x 3/4″ F
50627.xxx 50-500 lbf.ft 3/4″ M x 3/4″ F
50773.xxx 100-1000 lbf.ft 1″ M x 1″ F
50610.xxx* 1-10 lbf.in 1/4″ M x 1/4″ F
50612.xxx 2.5-25 lbf.in 1/4″ M x 1/4″ F
50614.xxx 5-50 lbf.in 1/4″ M x 1/4″ F
50617.xxx 10-100 lbf.in 1/4″ M x 1/4″ F
50619.xxx 25-250 lbf.in 3/8″ M x 3/8″ F
50621.xxx 50-500 lbf.in 3/8″ M x 3/8″ F
50623.xxx 100-1000 lbf.in 1/2″ M x 1/2″ F
50609.xxx* 10-100 ozf.in 1/4″ M x 1/4″ F
TD2.CCW Alternative calibration direction for transducers up to 1500 N.m / 1000 lbf.ft when ordered with new unit

M=Male F=Female
Standard Calibration is performed loading clockwise only

Cod STATIC TRANSDUCERS
50703.xxx 250-2500 N.m 1 1/2″ M x 1 1/2″ F
50791.xxx 300-3000 N.m 1 1/2″ M x 1 1/2″ F
50599.xxx 500-5000 N.m 1 1/2″ M x 1 1/2″ F
50669.xxx@ 700-7000 N.m 1 1/2″ M x 1 1/2″ F
50704.xxx 250-2500 lbf.ft 1 1/2″ M x 1 1/2″ F
50630.xxx 500-5000 lbf.ft 1 1/2″ M x 1 1/2″ F
TD5.CCW@ Alternative calibration direction for transducers from 1501 N.m to 7000 N.m / 1001 lbf.ft to 5000 lbf.ft when ordered with new unit
50776.xxx 1000-10000 N.m 2 1/2″ M x 2 1/2″ F
50603.xxx 2500-25000 N.m 2 1/2″ M x 2 1/2″ M
50797.xxx 2500-25000 N.m 2 1/2″ M x 2 1/2″ F
50781.xxx 5000-50000 N.m 2 1/2″ M x 2 1/2″ F
50794.xxx* 5000-50000 N.m 3 1/2″ M x 3 1/2″ M
50783.xxx 8000-80000 N.m 3 1/2″ M x 3 1/2″ F
50796.xxx 10000-100000 N.m 3 1/2″ M x 3 1/2″ M
50777.xxx 1000-10000 lbf.ft 2 1/2″ M x 2 1/2″ F
50633.xxx 1000-10000 lbf.ft 2 1/2″ M x 2 1/2″ M
50635.xxx 2500-25000 lbf.ft 2 1/2″ M x 2 1/2″ M
50798.xxx 2500-25000 lbf.ft 2 1/2″ M x 2 1/2″ F
50799.xxx 3000-30000 lbf.ft 2 1/2″ M x 2 1/2″ F
50795.xxx 5000-50000 lbf.ft 3 1/2″ M x 3 1/2″ M
50782.xxx 6000-60000 lbf.ft 3 1/2″ M x 3 1/2″ F
50637.xxx+ 10000-100000 lbf.ft 3 1/2″ M x 3 1/2″ M
TD3.CCW+ Alternative calibration direction for transducers from 7001 N.m to 100000 N.m / 5001 lbf.ft to 100000 lbf.ft when ordered with new unit
15000-150000 N.m 41/2″ M x 41/2″ M
20000-200000 N.m 41/2″ M x 41/2″ M

* .LOG versions not suitable for TST, TTT or TTL-HE, but can be used with T-Box.
@ UKAS accredited calibration up to 6000 N.m. A non accredited value at 7000 N.m is extrapolated and provided for reference only.
+ UKAS accredited calibration up to 80000 lbf.ft. A non accredited value at 100000 lbf.ft is extrapolated and provided for reference only.

Cod STATIC TRANSDUCERS
SECCAL.CW Secondary Calibration in one direction on static transducers with 2.5″ square drives to extend the range below 10% of the rated capacity, when ordered with new unit
SECCAL.CW+CCW Secondary Calibration in two directions on static transducers with 2.5″ square drives to extend the range below 10% of the rated capacity, when ordered with new unit
ADDCALPOINTS.NEW Additional calibration steps below 10% of rated capacity to 2% for transducers up to 7000 N.m(5000 lbf.ft) when ordered with new unit
Cod BENCH STANDS FOR STATIC TORQUE TRANSDUCERS
50211 Small frame size (10 N.m) 1/4″ sq.
50212 Small frame size (50 N.m) 3/8″ sq.
50213 Small frame size (100/250 N.m) 1/2″ sq.
50220 Large frame size (250/500 N.m) 3/4″ sq.
50221 Large frame size (1000/1500 N.m) 1″ sq.
50127.BLK9005 Extra large size (7000 N.m) 1 1/2″ sq.
52014 1/4″ Insert for Small Bench Stands
52015 3/8″ Insert for Small Bench Stands
52016 1/2″ Insert for Small Bench Stands
52017 3/4″ Insert for Large Bench Stands
52018 1″ Insert for Large Bench Stands
Cod ROTARY TRANSDUCERS
50708.xxx 0.25-5 N.m 1/4″ M/F Hex
50709.xxx 1-20 N.m 1/4″ M/F Hex
50710.xxx 1-20 N.m 1/4″ F/M sq. dr.
50719.xxx 0.75-15 lbf.ft 1/4″ F/M sq. dr.
50711.xxx 3.75-75 N.m 3/8″ F/M sq. dr.
50720.xxx 2.5-50 lbf.ft 3/8″ F/M sq. dr.
50712.xxx 10-200 N.m 1/2″ F/M sq. dr.
50721.xxx 7.5-150 lbf.ft 1/2″ F/M sq. dr.
50713.xxx 12.5-250 N.m 3/4″ F/M sq. dr.
50722.xxx 10-200 lbf.ft 3/4″ F/M sq. dr.
50714.xxx 25-500 N.m 3/4″ F/M sq. dr.
50723.xxx 15-300 lbf.ft 3/4″ F/M sq. dr.
50715.xxx 75-1500 N.m 1″ F/M sq. dr.
50724.xxx 50-1000 lbf.ft 1″ F/M sq. dr.
TD2.CCW Counter clockwise calibration.
Cod ANNULAR TRANSDUCERS FOR HT/ET/PTM-92
50753.xxx 270-2700 N.m 1″ sq. dr.
50793.xxx 400-4000 N.m 1″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR HT/ET/PTM-119 SERIES
50755.xxx 450-4500 N.m 1 1/2″ sq. dr.
50756.xxx 600-6000 N.m 1 1/2″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR 72MM SERIES GEARBOX (HT & PT)(Not suitable for PTM tools)
50666.xxx 100-1000 N.m
50667.xxx 150-1500 N.m
50668.xxx 200-2000 N.m
Cod ANNULAR TRANSDUCERS FOR SMALL DIAMETER SERIES GEARBOX (HT & PT) Suitable for HT60 and PT5500
50663.xxx 600-6000 N.m 1 1/2″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for PT1, PT1A and PT2
50638.xxx 100-1000 N.m 3/4″ sq. dr.
50648.xxx 100-1000 lbf.ft 3/4″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for heavy duty HT2, PT1, PT1A and PT2
50639.xxx 150-1500 N.m 1″ sq. dr.
50649.xxx 150-1500 lbf.ft 1″ sq. dr.
TD2.CCW Alternative calibration direction for transducers up to 1500 N.m / 1000 lbf.ft when ordered with new unit
50640.xxx 250-2500 N.m 1″ sq. dr.
50650.xxx 250-2500 lbf.ft 1″ sq. dr.
50641.xxx 350-3500 N.m 1″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for HT5 and PT5
50700.xxx 350-3500 N.m 1 1/2″ sq.dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for HT6 and PT6
50643.xxx 500-5000 N.m 1 1/2″ sq. dr.
50652.xxx 500-5000 lbf.ft 1 1/2″ sq. dr.
TD5.CCW@ Alternative calibration direction for transducers from 1501 N.m to 7000 N.m / 1001 lbf.ft to 5000 lbf.ft when ordered with new unit
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for HT9 and PT9
50644.xxx 1000-10000 N.m 1 1/2″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for HT12 and PT12
50645.xxx 2000-20000 N.m 2 1/2″ sq. dr.
50654.xxx 1500-15000 lbf.ft 2 1/2″ sq. dr.
50764.xxx 3500-35000 N.m 2 1/2″ sq. dr.
50765.xxx 2500-25000 lbf.ft 2 1/2″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for HT13 and PT13
50646.xxx 5000-50000 N.m 2 1/2″ sq. dr.
Cod ANNULAR TRANSDUCERS FOR STANDARD SERIES GEARBOX Suitable for PT14
50647.xxx 10000-100000 N.m 3 1/2″ sq. dr.
TD4.CCW Alternative calibration direction for tranducers from 7001 N.m to 100000 N.m / 5001 lbf.ft to 75000 lbf.ft when ordered with new unit – 30000-300000 N.m

Suitable for PT18.MTS
Standard Calibration is performed loading counter clockwise only.
@ UKAS accredited calibration up to 6000 N.m. A non accredited value
at 7000 N.m is extrapolated and provided

Cerere oferta pret